NHN-SEV-73
Ammonia nitrogen electorde

NT$100

  • Widely used in surface water, lake reservoirs, sewage treatment, etc.
  • Fast response for in-situ measurement
  • With automatic compensation function for temperature, pH and potassium ions
  • No chemical reagent or pre-treatment required, low maintenance costs
  • Stainless steel body, waterproof grade IP68
  • Excellent stability even for long-term monitoring
  • RS485 communication interface, standard Modbus protocol, easy to integrate

 

 

  • Working principle: Ion selective electrode method
  • Measuring range : 0.2~1000 mg/L NH4-N
  • Accuracy : ±5% FS
  • Resolution : 0.1 mg/L
  • Communications : RS485 interface, Modbus RTU protocol
  • Socket thread : 3/4”
  • Cable length : 3 m, other lengths can be customized
  • Protection : IP68
  • Working condition : 0~60°C / 0~3 bar
  • Power supply : 12V~24VDC