NT$100
Model : | A60-XPA-FCLP | |||||
---|---|---|---|---|---|---|
Model | A60-XPA-FCLP-E | A60-XPA-FCLP-S | A60-XPA-FCLP-P | |||
Range | 0~10.00 mg/L | |||||
Resolution | 0.01 mg/L | |||||
Accuracy | < ±5% F.S. | |||||
Temperature | Range 0~60 °C, resolution 0.1 °C, accuracy ±0.2 °C | |||||
Measurement principle | Three-pole polarography method (double platinum + reference electrode) | |||||
Response time | <60 sec (90%反應時間) | |||||
Inlet flow rate | 0.5 ~ 4 L/min | 0.5 ~ 4 L/min | 0.5 ~ 4 L/min | |||
Provide a simple flow cell, the user must control the flow rate, otherwise the measurement accuracy will be affected. | The flow cell has preliminary bubble filtering and flow and pressure stabilizing functions. | The flow cell has preliminary bubble filtering and flow and pressure stabilizing functions. | ||||
Flow rate detection | N/A | Optional | Optional | |||
A flow sensor can be installed for flow detection and water outage warning. | A flow sensor can be installed for flow detection and water outage warning. | |||||
Temp. Comp. | N/A | NTC10K automatic temperature compensation | NTC10K automatic temperature compensation | |||
(Compensation range : 0~50°C) | (Compensation range : 0~50°C) | |||||
pH measurement | N/A | N/A | Supports pH measurement, select appropriate electrode according to environment. | |||
pH compensation for residual chlorine | N/A | N/A | pH compensation can be turned off or on (range 5~9 pH) | |||
Automatic cleaning | Built-in cleaning relay to control the external cleaning device. The motor and rotor provide stable flow rate and reduce dirt adhesion on the electrode and flow cell. | |||||
Filter | Optional | |||||
Working/storage temperature | 0~50 °C | |||||
Calibration Mode | Zero, Span, Process adjustment | |||||
Display | TFT-LCD display | |||||
Language | English / Simplified Chinese / Traditional Chinese | |||||
Analog Output | Two sets of isolated 0/4~20mA corresponding to measurement, max load 500 Ω | |||||
Relay Settings | Two sets of Relays for High/Low point control, One set of Relay for timer settings | |||||
Measuring Chart | Corresponding to 4~20mA, display the measurement curve within 1 hour (average, maximum and minimum values per minute) | |||||
Digital Communication | MODBUS RTU, isolated | |||||
Clock | Clock is working when power off | |||||
Power Supply | 100V~240 VAC±10%,50/60 Hz,10W Max. | |||||
Installation | Panel mounting | Wall mounting | Wall mounting | |||
Inlet tube | 1/8" quick coupler | 7x9mm soft tube | 7x9mm soft tube | |||
Outlet tube | 1/8" quick coupler | 16x20mm soft tube | 16x20mm soft tube | |||
Dimensions | Transmitter : 96mm(H) × 96mm(W)×110mm(D) | 600mm(H) × 400mm(W) × 170mm(D) | 600mm(H) × 400mm(W) × 170mm(D) | |||
Flow cell : 163mm(H) × 64mm(W) | ||||||
Cutout Dimensions | Transmitter: 91.5 mm(H)×91.5 mm (W) | N/A | N/A | |||
Protection | N/A | IP65 (NEMA 4X equivalent) | IP65 (NEMA 4X equivalent) | |||
Weight | approx. 0.6 Kg | approx. 3.2 Kg | approx. 3.5 Kg |