A60-XPA-FCLP
Online FCL/HCLO/O3 Analyzer

NT$100

  • Simultaneously measure residual chlorine (or hypochlorous acid/ozone) and pH
  • No need to wait for polarization time
  • No need to add or replace electrolyte, easy subsequent maintenance
  • The flow tank has preliminary bubble filtering and stable flowrate and pressure functions (-S/-P model)
  • Optional flow meter and motor speed detection can be used to detect water outage and motor failure.
  • Contains a motor to control the magnet stirring speed (-S/-P model), so that the flow rate can be maintained constant
  • Using magnetic stirring instead of rotating electrodes can avoid complex mechanism design and maintenance costs.
  • DC brushless motor is used to avoid heat accumulation in the motor.

     

 

SKU: N/A Category:
  • Large Graphic LCD Display

  • User-friendly navigation system

 

 

  • 32 bits ARM-based MCU

 

  • CE certification

 

  • IP65 Protection

Specification

Model :A60-XPA-FCLP
ModelA60-XPA-FCLP-EA60-XPA-FCLP-SA60-XPA-FCLP-P
Range0~10.00 mg/L
Resolution0.01 mg/L
Accuracy< ±5% F.S.
TemperatureRange 0~60 °C, resolution 0.1 °C, accuracy ±0.2 °C
Measurement principleThree-pole polarography method (double platinum + reference electrode)
Response time<60 sec (90%反應時間)
Inlet flow rate0.5 ~ 4 L/min0.5 ~ 4 L/min0.5 ~ 4 L/min
Provide a simple flow cell, the user must control the flow rate, otherwise the measurement accuracy will be affected.The flow cell has preliminary bubble filtering and flow and pressure stabilizing functions.The flow cell has preliminary bubble filtering and flow and pressure stabilizing functions.
Flow rate detectionN/AOptionalOptional
A flow sensor can be installed for flow detection and water outage warning.A flow sensor can be installed for flow detection and water outage warning.
Temp. Comp.N/ANTC10K automatic temperature compensationNTC10K automatic temperature compensation
(Compensation range : 0~50°C)(Compensation range : 0~50°C)
pH measurementN/AN/ASupports pH measurement, select appropriate electrode according to environment.
pH compensation for residual chlorineN/AN/ApH compensation can be turned off or on (range 5~9 pH)
Automatic cleaningBuilt-in cleaning relay to control the external cleaning device.
The motor and rotor provide stable flow rate and reduce dirt adhesion on the electrode and flow cell.
FilterOptional
Working/storage temperature0~50 °C
Calibration ModeZero, Span, Process adjustment
DisplayTFT-LCD display
LanguageEnglish / Simplified Chinese / Traditional Chinese
Analog OutputTwo sets of isolated 0/4~20mA corresponding to measurement, max load 500 Ω
Relay SettingsTwo sets of Relays for High/Low point control, One set of Relay for timer settings
Measuring ChartCorresponding to 4~20mA, display the measurement curve within 1 hour (average, maximum and minimum values ​​per minute)
Digital CommunicationMODBUS RTU, isolated
ClockClock is working when power off
Power Supply100V~240 VAC±10%,50/60 Hz,10W Max.
InstallationPanel mountingWall mountingWall mounting
Inlet tube1/8" quick coupler7x9mm soft tube7x9mm soft tube
Outlet tube1/8" quick coupler16x20mm soft tube16x20mm soft tube
DimensionsTransmitter : 96mm(H) × 96mm(W)×110mm(D)600mm(H) × 400mm(W) × 170mm(D)600mm(H) × 400mm(W) × 170mm(D)
Flow cell : 163mm(H) × 64mm(W)
Cutout DimensionsTransmitter: 91.5 mm(H)×91.5 mm (W)N/AN/A
ProtectionN/AIP65 (NEMA 4X equivalent)IP65 (NEMA 4X equivalent)
Weightapprox. 0.6 Kgapprox. 3.2 Kgapprox. 3.5 Kg